Multi-point temperature control
system |
C
series |
- C series is a multi-channel temperature control system
which consists of features like a power source |
host link unit and 2-channel temperature control
unit. |
- Usage of a "CC-Link", link unit which allows you to
connect to higher speed open network. |
- Shinko touch panel unit can be connected to temperature
control unit without programming and easily |
performs various settings (setting parameter for
temperature control, temperature alarm function, |
heater burnout alarm function, etc). |
- By connecting to the PLC corresponding to "CC-LINK" or to
the other instruments or control instruments, |
even multiple tasks of monitoring can be carried out. |
 |
- Save space and wiring with small size |
- Interactive simple operation |
- Connectable to CC-Link compatible devices |
- Simple connection and removal ! |
|
|
2ch temperature control
unit |
CCT-235-2∴/∴ |
2 channels of input/output temperature control
unit |
Input |
: |
Thermocouple, RTD, DC Current, DC Voltage |
 |
Setting accuracy |
: |
Within ±0.3%FS±1digit |
Sampling period |
: |
0.25 seconds |
Control action |
: |
Auto-tuning PID, PD, ON/OFF |
Control output |
: |
Relay contact, Non-contact voltage, DC Current |
Power supply |
: |
5±0.2Vdc max 100mA, 12Vdc max. 50mA |
|
|
(The power is supplied by the CPT-200) |
External dimensions |
: |
24(W)x96(H)x94(D)mm |
Options |
: |
Heater burnout alarm, Terminal cover |
|
Heating/Cooling temperature control
unit |
CCT-235-∴/∴,
D∴ |
1 channel input/output Temperature control unit with
Heating/Cooling control |
Input |
: |
Thermocouple, RTD, DC Current, DC Voltage |
 |
Setting accuracy |
: |
Within ±0.2%FS±1digit |
Sampling period |
: |
0.25 seconds |
Control action |
: |
Auto-tuning PID, PD, ON/OFF |
Control output |
: |
Relay contact, Non-contact voltage, DC Current |
Power supply |
: |
5±0.2V DC max 100mA, 12V DC max. 50mA |
|
|
(The power is supplied by the CPT-200) |
External dimensions |
: |
24(W)x96(H)x94(D)mm |
Options |
: |
Heater burnout alarm, Terminal cover |
|
Power source host link
unit |
CPT-20A |
Link unit to supply power to the CCT-235 and for communication with
the touch panel unit, |
a host computer, etc. |
Host communication function |
: |
Communication line: Based on RS-422A (RS-485) |
|
 |
|
|
Communication method: Half-duplex |
|
|
communication start-stop synchronous |
|
|
Communication speed: 9600/19200bps |
|
|
Data format: Start bit (1), Data bit (7), |
|
|
Parity (Even), Stop bit (1) |
Power supply |
: |
100 to 240V AC 50/60Hz |
External dimensions |
: |
48(W)x96(H)x94(D)mm |
|
|
|
PLC interface
unit |
CIT-200 |
Link unit to connect between PLC and C series
instruments |
Communication line |
: |
Between PLC and CIT: |
|
 |
|
|
Based on RS-232C/RS-422A(RS-485) |
|
|
Between CPT and CIT: |
|
|
Based on RS-422A (RS-485) |
Communication function |
: |
Communication method: Half-duplex communication |
|
|
start/stop synchronous |
|
|
Communication speed: 9600/19200bps |
|
|
Data format: Start bit (1), Data bit (7, 8) |
|
|
Parity (None, Even, Odd), Stop bit (1) |
Power supply |
: |
100 to 240V AC 50/60Hz |
External dimensions |
: |
48(W)x96(H)x94(D)mm |
|
|
|
|
CC-Link link
unit |
CLT-200 |
Link unit to connect CC-Link master unit |
Setting |
: |
Following settings are available by rotary switch. |
 |
|
|
- CC-Link baud rate setting |
|
|
- CC-Link address setting (1 to 64) |
Host communication function |
: |
Communication line: CC-Link(RS-485) |
|
|
Communication method: Half-duplex communication |
|
|
start/stop synchronous |
|
|
Communication speed: 156k/625k/2.5M/5M/10Mbps |
Power supply |
: |
100 to 240V AC 50/60Hz |
External dimensions |
: |
24(W)x96(H)x94(D)mm |
|
|
|
Link unit to exchange data between PC and
CCT-235 |
Setting |
: |
Following settings are available by rotary switch. |
 |
|
|
- Communication baud rate setting to PC |
|
|
- Address of the PC Link unit |
Host communication function |
: |
Communication line: RS-232C/RS-422A(RS-485) |
|
|
Communication method: Half-duplex communication |
|
|
start/stop synchronous |
|
|
Communication speed: 2400/4800/9600/19200bps |
|
|
Data format: Start bit (1), Data bit (7), Parity (Even), |
|
|
Stop bit (1) |
Power supply |
: |
5±0.2V DC (The power is supplied by CPT-20A) |
External dimensions |
: |
24(W)x96(H)x94(D)mm |
|
|
|
Touch panel unit to set CCT-235 individually. Monitoring can be
carried out without programming. |
Display specifications |
: |
Device: Color LCD |
 |
|
|
Color: 16 out of 512 colors |
|
|
Size: 5.7 inches |
Input function |
: |
Switch system: Transparent conductive touch
switch |
|
|
Number of switch: 16x12 |
External interface |
: |
RS-232C (1 port), RS-485 (1 port) |
Power supply |
: |
24V DC |
External dimensions |
: |
195(W)x150(H)x47(D)mm |
|
|
|
The setting and monitoring can be performed one channel at a
time. |
Up to 20 points of temperature setting and monitoring can be
performed. |
Setting |
: |
Individual setting for CCT is possible by key operation. |
 |
Serial communication |
: |
Communication line: Based on RS-422A |
|
|
Communication method: Half-duplex communication |
|
|
start/stop synchronous |
|
|
Communication speed: 19200bps |
|
|
Data format: Start bit, Data bit |
|
|
Parity, Stop bit |
Power supply |
: |
100 to 240V AC 50/60Hz |
External dimensions |
: |
96(W)x96(H)x100(D)mm |
Options |
: |
Status output, Terminal cover |
|
|
|
Base unit to mount CPT, CCT and CLT. |
Model name |
: |
CBT-205; 1 unit of CPT-20A and max. 5 units of |
 |
|
|
CCT-235 can be connected. |
|
|
When connecting CC-Link compatible PLC, one |
|
|
CPT-20A unit, max. 4 units of CCT-235 and one |
|
|
CLT-200 unit can be connected. |
|
|
CBT-210; One CPT-20A unit and max. 10 units of |
|
|
CCT-235 can be connected. |
|
|
When connecting CC-Link compatible PLC, one |
|
|
CPT-20A unit, max. 8 units of CCT-235 and one |
|
|
CLT-200 unit can be connected. |
|
|
|
|
Communication
cable |
CPM,
CPP |
Communication cable for connecting CPT and CMT, COT or PLC, or for
increasing the blocks. |
Model name |
: |
CPM: Communication cable to connect between |
 |
|
|
CPT-20A and CMT-200, or between CPT-20A and |
|
|
COT-200 |
|
|
Cable length: 3m |
|
|
CPP: Communication cable to connect between CPT |
|
|
units (for increasing the blocks), or between CPT |
|
|
and CIT |
|
|
Cable length: 50cm |
|
|
|
|
|
|