Untitled Document
  sub1_left


Shinko products

WSP-100 (PH)

WSP-100 (ORP)

 

Shinko products

WSP-200 (PH)

WSP-200 (ORP)

 

 

Shinko products

PH(ORP)-6000

PH(ORP)-1000

 

 

Shinko products

PHSensor·ù

PHº¹ÇÕÀ¯¸®Àü±Ø

ORPSensor·ù

Holder·ù
   
Shinko products
PH-6000 FullBox
 

 

  • Multiple Measurements
    Analog outputs, measures value, temperature, relays can also be shown.
  • 4~20mA(0~20mA) Analog Outputs
    Isolated analog outputs can be set to 0~20mA or 4~20mA
  • Customized LCD readout
    Provides excellent viewing
  • NEMA 4X / IP65 Enclosure Case
  • Passcode-protected Access
    For security, use each Model¡¯s capability to restrict access to configuration settings and calibration to authorized personnel only.
  • OEM Versions Available
    Each analyzers can be manufactured to accommodate OEM -specific needs.
  • Free Voltage type
    100~240VAC, 50/60Hz (10 VA max.) available.

¡Ý Specification

Display

LCD

 

pH measurement

Measuring range

-1.00 to +15.00pH

 

Resolution

0.1pH

 

Accuracy

Max. 0.5% F.S

 

Repeatability

Glass type (Antimony type is optional)

 

Sensor to Analyzer Distance

50m (when junction box use with it)

Temperature

Measuring range

-10.0 to +110.0°C

 

Temp. element

Pt100RTD (Pt1000RTD is optional)

 

Temperature Compensation method

ATC, MTC

 

Temperature Compensation range

0 to +100.0°C

Analog Outputs

Analog Outputs

Isolated 0.00~20.00mA or 4.00~20.00mA

 

Load

MAX. 600ohm

Communication

Outputs

Using isolated half duplex

RS-485

Protocol

MODBUS-RTU

 

BAUD

1200 ~ 9600 bps

 

Max. distance

Max. 1.2km

Relay outputs

Relay type

SPST contact(UL)

 

Switching volt.

Max. AC250V, DC30V

 

Switching Current.

Max. 5A

 

Out Relay

3 Relay

 

Function

Alarm, Control, Timer(Performance of DIK sensor cleaning)
(Independently setup for relay output each channel are available)

Sensor Calibration

Method

2 point automatic calibration, 2 point manual calibration

 

Buffer solution

(Set of 1,68, 4.00, 7.00, 10.01pH) or
(Set of 1.68, 4.01, 6.86, 9.18 pH)

Hold Function

Auto Hold

When using of sensor cleaning or sensor calibrating

 

Manual Hold

When ON of HOLD Key

 

Alarm Control Relay

Available of operating method setup when HOLD

 

Analog outputs

HOLD to previous output values

Test Function

Relay contact test, analog outputs test, simulation test

Security Function

Pass code

Access to configuration settings and sensor calibration is available only by entering passcode. (Change of passcode is not available)

Ambient

Temperature rangetest

-20.0 ~ +60°C

Conditions

Storage Temp.

-25.0 ~ +65.0°C

 

Relative Humidity

Non-condensing 10 ~ 95%

 

Enclosure

NEMA4X / IP65

Housing

Mounting

pipe mounting / wall mounting

 

Dimension

241(H) x 192(W) x 90(D)mm

 

Weight

Approximately 2.7Kg

 

Material

Case (ADC3), Membrane Display panel (PC)

Power Supply

Supply Voltage

AC100 ~ 240V(-15% ~ +10%), 50/60Hz

 

Power Consumption

Max. 10VA

 


Untitled Document