PH-6000 FullBox
 


 

  • Multiple Measurements
    Analog outputs, measures value, temperature, relays can also be shown.
  • 4~20mA(0~20mA) Analog Output
    Isolated analog outputs can be set to 0~20mA or 4~20mA
  • Customized LCD readout
    Provides excellent viewing
  • Panel - mount 96 x 96 DIN case
  • Passcode-protected Access
    For security, use each Model¡¯s capability to restrict access to configuration settings and calibration to authorized personnel only.
  • OEM Versions Available
    Each analyzers can be manufactured to accommodate OEM -specific needs.
  • Free Voltage type
    100~240VAC, 50/60Hz (5 VA max.) available.

¡Ý Specification

Display

LCD

 

ORP measurement

Measuring range

-1500 to +1500mV

 

Resolution

1mV

 

Accuracy

Max. 0.5% F.S

 

Repeatability

Max. 0.2% F.S

 

Sensor to Analyzer Distance

50m(when junction box use with it)

Analog Outputs

Analog Outputs

Isolated 0.00~20.00mA or 4.00~20.00mA

 

Load

MAX. 600ohm

Communication

Outputs

Using isolated half duplex

RS-485

Protocol

MODBUS-RTU

 

BAUD

1200 ~ 9600 bps

 

Max. distance

Max. 1.2km

Relay outputs

Relay type

SPST contact(UL)

 

Switching volt.

Max. AC250V, DC30V

 

Switching Current.

Max. 5A

 

Out Relay

3 Relay

 

Function

Alarm, Control, Timer(Performance of DIK sensor cleaning)
(Independently setup for relay output each channel are available)

Sensor Calibration

Method

1 point manual calibration

Hold Function

Auto Hold

When using of sensor cleaning or sensor calibrating

 

Manual Hold

When ON of HOLD Key

 

Alarm Control Relay

Available of operating method setup when HOLD

 

Analog outputs

HOLD to previous output values

Test Function

Relay contact test, analog outputs test, simulation test

Security Function

Pass code

Access to configuration settings and sensor calibration is available only by entering passcode. (Change of passcode is not available)

Ambient Conditions

Temperature range

-20.0 ~ +60°C

 

Storage Temp

-25.0 ~ +65.0°C

 

Relative Humidity

Non-condensing 10 ~ 95%

 

Enclosure

IP54(Front panel)

Housing

Mounting

Panel mounting

 

Dimension

96(H) x 96(W) x 99(D)mm

 

Depth

Approximately 91mm

 

Weight

Approximately 0.5Kg

 

Material

ABS

Power Supply

Supply Voltage

AC100 ~ 240V(-15% ~ +10%), 50/60Hz

 

Power Consumption

Max. 5VA

 